[. . . ] Electric Dryer
PRODUCT MODEL NUMBERS WED7505F, WED75HEF, WED7740F, WED77HEF, WED8540F, WED85HEF, WED90HEF, WED92HEF
Dryer Dimensions
Front view:
27" (686 mm)
Installation spacing for recessed area or closet installation
All dimensions show recommended and minimum spacing allowed.
■■ Additional spacing should be considered for ease of
installation and servicing.
383/4" Min. [. . . ] Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
The “Vent System Charts” provide venting requirements that will help achieve best drying performance.
Standard Vent System Chart
Number of 90° elbows Type of vent Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Angled hoods 64 ft. (8. 2 m)
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS. Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. ■■ Only a 4" (102 mm) heavy metal exhaust vent and clamps may be used.
■■ Do not use plastic or metal foil vent.
0 1 2 3 4
Exhaust hoods: Recommended Styles:
Long Vent System Chart
Number of 90° elbows Type of vent Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Angled hoods 160 ft. (36. 6 m)
0 1
Louvered Hood Box Hood
2 3 4
Acceptable Style:
Angled Hood
Determine vent path:
■■ Select route that will provide straightest and most direct
path outdoors.
To determine if your model has a long vent system, refer to the type code located on the serial number plate in the inner door well. Example: An electric model would be DALV (Long Vent) – ELE – XXXXXXX-XXX. [. . . ] For complete details, see Installation Instructions packed with product. [. . . ]